Participants: | Participants: Satoshi Tanioka, Kenta Tanaka, Naoki Koyama, Chiaki Hirose, Kentaro Somiya, Kiwamu Izumi, Koji Nagano, Marc Eisenmann, Masayuki Nakano, Naoki Aritomi, Shoichi Oshino, Tomotada Akutsu, Yua Michimura |
Line 14: | Line 14: |
* Interferometer alignment * For O4, ISS setup will be removed from IMMT1T table but IMMT1 oplev setup will remain. We should take care if it affect IMMT1T QPD signals. * |
|
Line 19: | Line 22: |
* Other recent topics | * Are we going to remove ISS setup at IMMT1T? * Any upgrades necessary for IMC ASC? * Can we automate the beam centering with Tcams for reproducibility? * Any thoughts on why PRMI alignment has to be done before Yarm alignment? * Are there better ways for daily alignment? * What are the steps necessary for engaging WFS/QPD loops in O4? * Other recent topics related to ISC * Fiber noise cancellation improvement plans for ALS [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12769|JGW-T2112769]] (Tanioka) * Non-polarized beam splitter https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=10506 [Michimura] * IMC REFL: Thorlabs BSW11 are used (Ts=~40%) * IMC TRANS: Probably Thorlabs BSW11 are used * REFL: Note that p-pol is coming out from the chamber. Newport 10Q20HBS.33S (for s-pol) are used. Thin film polarizers are also used and there seems to be a confusion. * POP: Newport 10Q20HBS.33S (for s-pol) is used. S-pol/P-pol power ratio can be confused with this BS. * POS: No BS placed. * AS: p-pol is coming out from the chamber. We agreed to use HWP to make them s-pol and to use Newport 10Q20HBS.33S (for s-pol). But this solution might be confusing. * Planning to order non-polarized BS soon. * In-vac steering mirrors: https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12592 [Michimura] * For some steering mirrors, p-pol beam * STM1, STM2, POM1, POM2 around IFI (PYD-20 is used) * steering mirrors after OFI * PYD-20 has a transmission * T < 70ppm at 0 deg for s-pol (measured) * T < 25ppm at 30 deg for s-pol (measured) * T < 5ppm at 45 deg for s-pol (measured) * T ~ 1000pppm at 45 deg for p-pol (specsheet) * Also, specs of POP_POM and POS_POM for IR p-pol needs to be investigated * Optical table cover for TRX/TRY and IMC REFL/IMC TRANS: [[KAGRA/subgroup/ifo/MIF/Minutes20210412|Review page]] [Michimura] |
ISC Meeting on 2020/04/13 13:00 - 15:00
Participants: Satoshi Tanioka, Kenta Tanaka, Naoki Koyama, Chiaki Hirose, Kentaro Somiya, Kiwamu Izumi, Koji Nagano, Marc Eisenmann, Masayuki Nakano, Naoki Aritomi, Shoichi Oshino, Tomotada Akutsu, Yua Michimura
Zoom meeting: https://zoom.us/j/6676627462
Your time zone: https://www.timeanddate.com/worldclock/fixedtime.html?iso=20210413T0400
Next meeting
TBD
Minutes
- Interferometer alignment
- For O4, ISS setup will be removed from IMMT1T table but IMMT1 oplev setup will remain. We should take care if it affect IMMT1T QPD signals.
Agenda
Summary of interferometer alignment in O3GK and RSE commissioning JGW-T2112594 (Michimura)
- Discussion on how to proceed for O4
- Are we going to remove ISS setup at IMMT1T?
- Any upgrades necessary for IMC ASC?
- Can we automate the beam centering with Tcams for reproducibility?
- Any thoughts on why PRMI alignment has to be done before Yarm alignment?
- Are there better ways for daily alignment?
- What are the steps necessary for engaging WFS/QPD loops in O4?
- Other recent topics related to ISC
Fiber noise cancellation improvement plans for ALS JGW-T2112769 (Tanioka)
Non-polarized beam splitter https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=10506 [Michimura]
- IMC REFL: Thorlabs BSW11 are used (Ts=~40%)
- IMC TRANS: Probably Thorlabs BSW11 are used
- REFL: Note that p-pol is coming out from the chamber. Newport 10Q20HBS.33S (for s-pol) are used. Thin film polarizers are also used and there seems to be a confusion.
- POP: Newport 10Q20HBS.33S (for s-pol) is used. S-pol/P-pol power ratio can be confused with this BS.
- POS: No BS placed.
- AS: p-pol is coming out from the chamber. We agreed to use HWP to make them s-pol and to use Newport 10Q20HBS.33S (for s-pol). But this solution might be confusing.
- Planning to order non-polarized BS soon.
In-vac steering mirrors: https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12592 [Michimura]
- For some steering mirrors, p-pol beam
- STM1, STM2, POM1, POM2 around IFI (PYD-20 is used)
- steering mirrors after OFI
- PYD-20 has a transmission
T < 70ppm at 0 deg for s-pol (measured)
T < 25ppm at 30 deg for s-pol (measured)
T < 5ppm at 45 deg for s-pol (measured)
- T ~ 1000pppm at 45 deg for p-pol (specsheet)
- Also, specs of POP_POM and POS_POM for IR p-pol needs to be investigated
- For some steering mirrors, p-pol beam
Optical table cover for TRX/TRY and IMC REFL/IMC TRANS: Review page [Michimura]