= Viewports on Vacuum Chambers (at Room Temperature) = = Viewports (at Room Temperature) =
'''''Related subsystems:''''' IOO, MIF, VAC, CRY, VIS...
Line 3: Line 4:
<<TableOfContents(2)>> <<TableOfContents(3)>>
Line 6: Line 7:
This subsystem provides the optical viewports to pass through the optical beams from the vacuum chambers including LCGT main interferometer. This subsystem provides the optical viewports to pass through the optical beams from the vacuum chambers in which LCGT main interferometer is stored.
Line 9: Line 10:
The viewport subsystems applied to the cryo-vacuum chambers for ITMs/ETMs of the future LCGT are NOT included in the scope of this subsystem so far. The viewport subsystems that will be applied to the cryo-vacuum chambers for ITMs/ETMs of the future LCGT are '''NOT''' included in the scope of this subsystem so far.
Line 11: Line 12:
== Introduction ==

=== Applicable Documents ===

=== Definitions ===
== Applicable Documents ==
 * Optical Layout Drawing of the LCGT interferometer
 * Length Sensing doc
 * Alignment Sensing doc
 * Optical lever doc
 * CCD Monitor doc
 * Any...
Line 19: Line 21:
We can extract optical beams from the interferometer inside the vacuum chamber at the viewports.
The optical beams are for length control scheme of the interferometer, alignment control scheme of the mirrors, optical levers for LCGT-SUS, and other monitoring devices (CCD or equivalent video cameras).
Line 20: Line 24:
== Naming Conventions == Stray lights?
Line 22: Line 26:
== Viewport Locations ==  * AR coating for 1064 nm and 532 nm
 * Wedge angle
Details are described in ''Characteristics'' section.

=== Naming Conventions ===

=== Locations ===
 * BS chamber
 *

== Characteristics ==

Viewports (at Room Temperature)

Related subsystems: IOO, MIF, VAC, CRY, VIS...


Scope

This subsystem provides the optical viewports to pass through the optical beams from the vacuum chambers in which LCGT main interferometer is stored. The optical beams include...

The viewport subsystems that will be applied to the cryo-vacuum chambers for ITMs/ETMs of the future LCGT are NOT included in the scope of this subsystem so far.

Applicable Documents

  • Optical Layout Drawing of the LCGT interferometer
  • Length Sensing doc
  • Alignment Sensing doc
  • Optical lever doc
  • CCD Monitor doc
  • Any...

General Description

We can extract optical beams from the interferometer inside the vacuum chamber at the viewports. The optical beams are for length control scheme of the interferometer, alignment control scheme of the mirrors, optical levers for LCGT-SUS, and other monitoring devices (CCD or equivalent video cameras).

Stray lights?

  • AR coating for 1064 nm and 532 nm
  • Wedge angle

Details are described in Characteristics section.

Naming Conventions

Locations

  • BS chamber

Characteristics