Differences between revisions 1 and 25 (spanning 24 versions)
Revision 1 as of 2011-07-02 22:52:28
Size: 742
Comment:
Revision 25 as of 2011-07-03 00:20:50
Size: 1531
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
= Viewports on Vacuum Chambers (at Room Temperature) = = Viewports (at Room Temperature) =
'''''Related subsystems:''''' IOO, MIF, VAC, CRY, VIS...
Line 3: Line 4:
<<TableOfContents(2)>> <<TableOfContents(3)>>
Line 6: Line 7:
This subsystem provides the optical viewports to pass through the optical beams from the vacuum chambers including LCGT main interferometer. This subsystem provides the optical viewports to pass through the optical beams from the vacuum chambers in which LCGT main interferometer is stored.
Line 9: Line 10:
The viewport subsystems applied to the cryo-vacuum chambers for ITMs/ETMs of the future LCGT are NOT included in the scope of this subsystem so far. The viewport subsystems that will be applied to the cryo-vacuum chambers for ITMs/ETMs of the future LCGT are '''NOT''' included in the scope of this subsystem so far.
Line 11: Line 12:
== Introduction == == Applicable Documents ==
 * Spec. for vacuum chambers
 * Optical Layout Drawing of the LCGT interferometer
 * Length Sensing doc
 * Alignment Sensing doc
 * Optical lever doc
 * CCD Monitor doc
 * Any...
Line 13: Line 21:
=== Applicable Documents === == General Description ==
We can extract optical beams at the viewports from the interferometer inside the vacuum chamber.
The optical beams are for length control scheme of the interferometer, alignment control scheme of the mirrors, optical levers for LCGT-SUS, and other monitoring devices (CCD or equivalent video cameras).
Line 15: Line 25:
=== Definitions === Stray lights?

 * AR coating for 1064 nm and 532 nm
 * Wedge angle
Details are described in ''Characteristics'' section.
Line 18: Line 32:
== General Description == === Functions ===
 * Optical Lever
 * Video camera
 * Illumination
 * Diagnostic
 * Squeeze
 * Spare
Line 20: Line 40:
== Naming Conventions == === Naming Conventions ===
Line 22: Line 42:
== Viewport Locations == === Locations ===
 * BS chamber
 *

== Characteristics ==

Viewports (at Room Temperature)

Related subsystems: IOO, MIF, VAC, CRY, VIS...


Scope

This subsystem provides the optical viewports to pass through the optical beams from the vacuum chambers in which LCGT main interferometer is stored. The optical beams include...

The viewport subsystems that will be applied to the cryo-vacuum chambers for ITMs/ETMs of the future LCGT are NOT included in the scope of this subsystem so far.

Applicable Documents

  • Spec. for vacuum chambers
  • Optical Layout Drawing of the LCGT interferometer
  • Length Sensing doc
  • Alignment Sensing doc
  • Optical lever doc
  • CCD Monitor doc
  • Any...

General Description

We can extract optical beams at the viewports from the interferometer inside the vacuum chamber. The optical beams are for length control scheme of the interferometer, alignment control scheme of the mirrors, optical levers for LCGT-SUS, and other monitoring devices (CCD or equivalent video cameras).

Stray lights?

  • AR coating for 1064 nm and 532 nm
  • Wedge angle

Details are described in Characteristics section.

Functions

  • Optical Lever
  • Video camera
  • Illumination
  • Diagnostic
  • Squeeze
  • Spare

Naming Conventions

Locations

  • BS chamber

Characteristics