Differences between revisions 13 and 61 (spanning 48 versions)
Revision 13 as of 2011-07-02 23:31:33
Size: 1279
Comment:
Revision 61 as of 2012-09-16 20:35:57
Size: 4005
Editor: KiwamuIzumi
Comment:
Deletions are marked like this. Additions are marked like this.
Line 2: Line 2:
Related subsystems: IOO, MIF, VAC, CRY,... '''''Related subgroups:''''' MIR, IOO, MIF, VAC, CRY, VIS...
Line 4: Line 4:
'''[[KAGRA/Subgroups/AOS| back to AOS top]]'''
Line 7: Line 9:
This subsystem provides the optical viewports to pass through the optical beams from the vacuum chambers in which LCGT main interferometer is stored. This subsystem provides the optical viewports mounted on the vacuum chambers to pass the optical beams into or from the LCGT in-vacuum interferometer.
Line 10: Line 12:
The viewport subsystems that will be applied to the cryo-vacuum chambers for ITMs/ETMs of the future LCGT are '''NOT''' included in the scope of this subsystem so far. Cryo-vacuum viewports are '''NOT''' included in the scope of this subsystem so far.
Line 12: Line 14:
== Introduction ==
We can extract optical beams from the interferometer inside the vacuum chamber at the viewports.
The optical beams are for length control scheme of the interferometer, alignment control scheme of the mirrors, optical levers for LCGT-SUS, and other monitoring devices (CCD or equivalents).

Stray lights?

=== Applicable Documents ===
== Applicable Documents ==
 * Spec. for vacuum chambers
Line 20: Line 17:
 * Length Sensing doc
 * Alignment Sensing doc
 * Length Sensing and Control doc
 * Alignment Sensing and Control doc
Line 26: Line 23:
=== Definitions === == General Description ==
At the viewports, we can extract optical beams from the interferometer placed inside the vacuum chambers.
The optical beams would be utilized for length and alignment sensing and control scheme, optical levers for suspensions, and other monitoring devices (CCD or equivalent video cameras).

For example, the viewport would be equipped with
 * AR coating for 1064 nm and 532 nm
 * Wedge angle
Details are described in ''Characteristics'' section.
Line 29: Line 33:
== General Description == === Functions ===
Beams for
 * Transmission of IR/Green lasers
 * Optical Lever transmitter/receiver
 * Video camera
 * Illumination
 * Diagnostic
 * (Squeeze)
 * (Spare)
Line 31: Line 43:
== Naming Conventions == === Naming Conventions ===
TBD
Line 33: Line 46:
== Viewport Locations ==
 * BS chamber
 *
Line 37: Line 47:
== Links ==
 * [[https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=29666&version=1|LIGO-T1000746-v1, Viewports Subsystem Final Design Document]]
<<Anchor(Locations)>>
=== Locations ===
Here, the number of viewports required by each subsystem at each vacuum chamber is listed.

||<#FFFF00>Chamber Name||<#FFFF00>Type||<#FFFF00>Quantity||<#FFFF00>Purpose||<#FFFF00>Used By||
||PRM||1064nm AR||1||REFL port||ISC||
||PRM||!OpLev wavelength||2||!OpLev||AOS/SUS||
||PRM ||Visible||1||CCD||Everyone||
||PR2||1064nm&532 dichroic AR||1 or 2||POP/Green||ISC||
||PR2||!OpLev wavelength||2||!OpLev||AOS/SUS||
||PR2 ||Visible||1||CCD||Everyone||
||PR3||!OpLev wavelength||2||!OpLev||AOS/SUS||
||PR3 ||Visible||1||CCD||Everyone||
||BS ||1064nm AR||1||POX/POY beams||ISC||
||BS ||!OpLev wavelength||2||Optical Lever||AOS/SUS||
||BS ||Visible||1||CCD||Everyone||
||ITMX||!OpLev wavelength||2||!OpLev||AOS/SUS||
||ITMX||Visible||1||CCD||Everyone||
||ITMY||!OpLev wavelength||2||!OpLev||AOS/SUS||
||ITMY||Visible||1||CCD||Everyone||
||ETMX||1064nm&532 dichroic AR||1||Transmission||ISC||
||ETMX||!OpLev wavelength||2||!OpLev||AOS/SUS||
||ETMX||Visible||1||CCD||Everyone||
||ETMY||1064nm&532 dichroic AR||1||Transmission||ISC||
||ETMY||!OpLev wavelength||2||!OpLev||AOS/SUS||
||ETMY||Visible||1||CCD||Everyone||
||SRM||1064nm AR||1||AS port||ISC||
||SRM||!OpLev wavelength||2||!OpLev||AOS/SUS||
||SRM ||Visible||1||CCD||Everyone||
||SR2||1064nm&532 dichroic AR||1 or 2||POS/Green||ISC||
||SR2||!OpLev wavelength||2||!OpLev||AOS/SUS||
||SR2 ||Visible||1||CCD||Everyone||
||SR3||!OpLev wavelength||2||!OpLev||AOS/SUS||
||SR3 ||Visible||1||CCD||Everyone||


== Requirements ==
TBD

== Characteristics ==
TBD


== Inspection plans ==
See [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=1231|JGW-T1201231, Effect due to viewports for optical lever (in Japanese)]]


== Procurement process and plans ==
TBD


== External Links ==
 * [[https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=29666|LIGO-T1000746-v1, Viewports Subsystem Final Design Document]]
 * [[https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=13226|LIGO-E1000246, 6.0 inch Vacuum Viewport Specification]]
 * [[https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=61876|LIGO-T1100292, Viewport Source List]]
 * [[https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=39955|LIGO-E1100247, Viewport Production Plan]]


 * [[https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=8509|LIGO-T1000022-v4, Viewports Subsystem Requirements Document]]
 * [[https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=12798|LIGO-T1000334-v1, Review Report Interferometer Sensing and Control Final Design]]

Viewports (at Room Temperature)

Related subgroups: MIR, IOO, MIF, VAC, CRY, VIS...


back to AOS top

Scope

This subsystem provides the optical viewports mounted on the vacuum chambers to pass the optical beams into or from the LCGT in-vacuum interferometer. The optical beams include...

Cryo-vacuum viewports are NOT included in the scope of this subsystem so far.

Applicable Documents

  • Spec. for vacuum chambers
  • Optical Layout Drawing of the LCGT interferometer
  • Length Sensing and Control doc
  • Alignment Sensing and Control doc
  • Optical lever doc
  • CCD Monitor doc
  • Any...

General Description

At the viewports, we can extract optical beams from the interferometer placed inside the vacuum chambers. The optical beams would be utilized for length and alignment sensing and control scheme, optical levers for suspensions, and other monitoring devices (CCD or equivalent video cameras).

For example, the viewport would be equipped with

  • AR coating for 1064 nm and 532 nm
  • Wedge angle

Details are described in Characteristics section.

Functions

Beams for

  • Transmission of IR/Green lasers
  • Optical Lever transmitter/receiver
  • Video camera
  • Illumination
  • Diagnostic
  • (Squeeze)
  • (Spare)

Naming Conventions

TBD

Locations

Here, the number of viewports required by each subsystem at each vacuum chamber is listed.

Chamber Name

Type

Quantity

Purpose

Used By

PRM

1064nm AR

1

REFL port

ISC

PRM

OpLev wavelength

2

OpLev

AOS/SUS

PRM

Visible

1

CCD

Everyone

PR2

1064nm&532 dichroic AR

1 or 2

POP/Green

ISC

PR2

OpLev wavelength

2

OpLev

AOS/SUS

PR2

Visible

1

CCD

Everyone

PR3

OpLev wavelength

2

OpLev

AOS/SUS

PR3

Visible

1

CCD

Everyone

BS

1064nm AR

1

POX/POY beams

ISC

BS

OpLev wavelength

2

Optical Lever

AOS/SUS

BS

Visible

1

CCD

Everyone

ITMX

OpLev wavelength

2

OpLev

AOS/SUS

ITMX

Visible

1

CCD

Everyone

ITMY

OpLev wavelength

2

OpLev

AOS/SUS

ITMY

Visible

1

CCD

Everyone

ETMX

1064nm&532 dichroic AR

1

Transmission

ISC

ETMX

OpLev wavelength

2

OpLev

AOS/SUS

ETMX

Visible

1

CCD

Everyone

ETMY

1064nm&532 dichroic AR

1

Transmission

ISC

ETMY

OpLev wavelength

2

OpLev

AOS/SUS

ETMY

Visible

1

CCD

Everyone

SRM

1064nm AR

1

AS port

ISC

SRM

OpLev wavelength

2

OpLev

AOS/SUS

SRM

Visible

1

CCD

Everyone

SR2

1064nm&532 dichroic AR

1 or 2

POS/Green

ISC

SR2

OpLev wavelength

2

OpLev

AOS/SUS

SR2

Visible

1

CCD

Everyone

SR3

OpLev wavelength

2

OpLev

AOS/SUS

SR3

Visible

1

CCD

Everyone

Requirements

TBD

Characteristics

TBD

Inspection plans

See JGW-T1201231, Effect due to viewports for optical lever (in Japanese)

Procurement process and plans

TBD

LCGT/subgroup/AOS/Viewport1 (last edited 2012-09-16 20:40:35 by KiwamuIzumi)