Differences between revisions 15 and 24 (spanning 9 versions)
Revision 15 as of 2011-07-02 23:39:42
Size: 1318
Comment:
Revision 24 as of 2011-07-02 23:57:17
Size: 1419
Comment:
Deletions are marked like this. Additions are marked like this.
Line 2: Line 2:
Related subsystems: IOO, MIF, VAC, CRY, VIS... '''''Related subsystems:''''' IOO, MIF, VAC, CRY, VIS...
Line 12: Line 12:
== Introduction ==
We can extract optical beams from the interferometer inside the vacuum chamber at the viewports.
The optical beams are for length control scheme of the interferometer, alignment control scheme of the mirrors, optical levers for LCGT-SUS, and other monitoring devices (CCD or equivalents).

Stray lights?

=== Applicable Documents ===
== Applicable Documents ==
 * Spec. for vacuum chambers
Line 26: Line 21:
=== Definitions === == General Description ==
We can extract optical beams at the viewports from the interferometer inside the vacuum chamber.
The optical beams are for length control scheme of the interferometer, alignment control scheme of the mirrors, optical levers for LCGT-SUS, and other monitoring devices (CCD or equivalent video cameras).
Line 28: Line 25:
Stray lights?
Line 29: Line 27:
== General Description ==
AR coating for 1064 nm and 532 nm
 * AR coating for 1064 nm and 532 nm
 * Wedge angle
Details are described in ''Characteristics'' section.
Line 32: Line 31:
== Naming Conventions == === Naming Conventions ===
Line 34: Line 33:
== Viewport Locations == === Locations ===
Line 38: Line 37:
== Characteristics ==

Viewports (at Room Temperature)

Related subsystems: IOO, MIF, VAC, CRY, VIS...


Scope

This subsystem provides the optical viewports to pass through the optical beams from the vacuum chambers in which LCGT main interferometer is stored. The optical beams include...

The viewport subsystems that will be applied to the cryo-vacuum chambers for ITMs/ETMs of the future LCGT are NOT included in the scope of this subsystem so far.

Applicable Documents

  • Spec. for vacuum chambers
  • Optical Layout Drawing of the LCGT interferometer
  • Length Sensing doc
  • Alignment Sensing doc
  • Optical lever doc
  • CCD Monitor doc
  • Any...

General Description

We can extract optical beams at the viewports from the interferometer inside the vacuum chamber. The optical beams are for length control scheme of the interferometer, alignment control scheme of the mirrors, optical levers for LCGT-SUS, and other monitoring devices (CCD or equivalent video cameras).

Stray lights?

  • AR coating for 1064 nm and 532 nm
  • Wedge angle

Details are described in Characteristics section.

Naming Conventions

Locations

  • BS chamber

Characteristics