Differences between revisions 21 and 34 (spanning 13 versions)
Revision 21 as of 2011-07-02 23:53:26
Size: 1384
Comment:
Revision 34 as of 2011-07-03 01:32:46
Size: 1722
Comment:
Deletions are marked like this. Additions are marked like this.
Line 2: Line 2:
'''''Related subsystems:''''' IOO, MIF, VAC, CRY, VIS... '''''Related subgroups:''''' MIR, IOO, MIF, VAC, CRY, VIS...
Line 13: Line 13:
 * Spec. for vacuum chambers
Line 21: Line 22:
We can extract optical beams from the interferometer inside the vacuum chamber at the viewports. We can extract optical beams at the viewports from the interferometer inside the vacuum chamber.
Line 24: Line 25:
Stray lights? Damping stray lights?
Line 30: Line 31:
== Naming Conventions ==
Line 32: Line 32:
== Locations == === Functions ===

 * Optical Lever
 * Video camera
 * Illumination
 * Diagnostic
 * Squeeze
 * (Spare)

=== Naming Conventions ===

=== Locations ===
Line 36: Line 47:
== Requirements ==
Line 37: Line 50:

== Inspection plans ==
Line 40: Line 55:
 * [[https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=8509|LIGO-T1000022-v4, Viewports Subsystem Requirements Document]]

Viewports (at Room Temperature)

Related subgroups: MIR, IOO, MIF, VAC, CRY, VIS...


Scope

This subsystem provides the optical viewports to pass through the optical beams from the vacuum chambers in which LCGT main interferometer is stored. The optical beams include...

The viewport subsystems that will be applied to the cryo-vacuum chambers for ITMs/ETMs of the future LCGT are NOT included in the scope of this subsystem so far.

Applicable Documents

  • Spec. for vacuum chambers
  • Optical Layout Drawing of the LCGT interferometer
  • Length Sensing doc
  • Alignment Sensing doc
  • Optical lever doc
  • CCD Monitor doc
  • Any...

General Description

We can extract optical beams at the viewports from the interferometer inside the vacuum chamber. The optical beams are for length control scheme of the interferometer, alignment control scheme of the mirrors, optical levers for LCGT-SUS, and other monitoring devices (CCD or equivalent video cameras).

Damping stray lights?

  • AR coating for 1064 nm and 532 nm
  • Wedge angle

Details are described in Characteristics section.

Functions

  • Optical Lever
  • Video camera
  • Illumination
  • Diagnostic
  • Squeeze
  • (Spare)

Naming Conventions

Locations

  • BS chamber

Requirements

Characteristics

Inspection plans