Differences between revisions 29 and 40 (spanning 11 versions)
Revision 29 as of 2011-07-03 00:37:10
Size: 1583
Comment:
Revision 40 as of 2011-07-03 02:03:33
Size: 1854
Comment:
Deletions are marked like this. Additions are marked like this.
Line 2: Line 2:
'''''Related subsystems:''''' MIR, IOO, MIF, VAC, CRY, VIS... '''''Related subgroups:''''' MIR, IOO, MIF, VAC, CRY, VIS...
Line 7: Line 7:
This subsystem provides the optical viewports to pass through the optical beams from the vacuum chambers in which LCGT main interferometer is stored. This subsystem provides the optical viewports to pass through the optical beams from the LCGT in-vacuum interferometer.
Line 15: Line 15:
 * Length Sensing doc
 * Alignment Sensing doc
 * Length Sensing and Control doc
 * Alignment Sensing and Control doc
Line 23: Line 23:
The optical beams are for length control scheme of the interferometer, alignment control scheme of the mirrors, optical levers for LCGT-SUS, and other monitoring devices (CCD or equivalent video cameras). The optical beams are for length and alignment sensing and control scheme, optical levers for LCGT-SUS, and other monitoring devices (CCD or equivalent video cameras).
Line 25: Line 25:
Damping stray lights? Dumping stray light beams?
Line 33: Line 33:
 * Photocal
Line 39: Line 39:
 * Spare  * (Spare)
Line 42: Line 42:
TBD
Line 47: Line 48:
== Requirements ==
TBD
Line 48: Line 52:
TBD
Line 50: Line 56:
TBD
Line 53: Line 60:
 * [[https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=8509|LIGO-T1000022-v4, Viewports Subsystem Requirements Document]]
 * [[https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=12798|LIGO-T1000334-v1, Review Report Interferometer Sensing and Control Final Design]]

Viewports (at Room Temperature)

Related subgroups: MIR, IOO, MIF, VAC, CRY, VIS...


Scope

This subsystem provides the optical viewports to pass through the optical beams from the LCGT in-vacuum interferometer. The optical beams include...

The viewport subsystems that will be applied to the cryo-vacuum chambers for ITMs/ETMs of the future LCGT are NOT included in the scope of this subsystem so far.

Applicable Documents

  • Spec. for vacuum chambers
  • Optical Layout Drawing of the LCGT interferometer
  • Length Sensing and Control doc
  • Alignment Sensing and Control doc
  • Optical lever doc
  • CCD Monitor doc
  • Any...

General Description

We can extract optical beams at the viewports from the interferometer inside the vacuum chamber. The optical beams are for length and alignment sensing and control scheme, optical levers for LCGT-SUS, and other monitoring devices (CCD or equivalent video cameras).

Dumping stray light beams?

  • AR coating for 1064 nm and 532 nm
  • Wedge angle

Details are described in Characteristics section.

Functions

  • Optical Lever
  • Video camera
  • Illumination
  • Diagnostic
  • Squeeze
  • (Spare)

Naming Conventions

TBD

Locations

  • BS chamber

Requirements

TBD

Characteristics

TBD

Inspection plans

TBD