= Viewports on Vacuum Chambers (at Room Temperature) = = Viewports (at Room Temperature) =
Related subsystems: IOO, MIF, VAC, CRY, VIS...
Line 6: Line 7:
This subsystem provides the optical viewports to pass through the optical beams from the vacuum chambers including LCGT main interferometer. This subsystem provides the optical viewports to pass through the optical beams from the vacuum chambers in which LCGT main interferometer is stored.
Line 11: Line 12:
== Applicable Documents ==
 * Optical Layout Drawing of the LCGT interferometer
 * Length Sensing doc
 * Alignment Sensing doc
 * Optical lever doc
 * CCD Monitor doc
 * Any...
Line 12: Line 21:
We can extract optical beams from the interferometer inside the vacuum chamber at the viewports.
The optical beams are for length control scheme of the interferometer, alignment control scheme of the mirrors, optical levers for LCGT-SUS, and other monitoring devices (CCD or equivalent video cameras).
Line 13: Line 24:
=== Applicable Documents ===

=== Definitions ===
Stray lights?
Line 19: Line 27:
 * AR coating for 1064 nm and 532 nm
 * Wedge angle
Details are described in ''Characteristics'' section.
Line 23: Line 34:
 * BS chamber
 *

== Characteristics ==

Viewports (at Room Temperature)

Related subsystems: IOO, MIF, VAC, CRY, VIS...


Scope

This subsystem provides the optical viewports to pass through the optical beams from the vacuum chambers in which LCGT main interferometer is stored. The optical beams include...

The viewport subsystems that will be applied to the cryo-vacuum chambers for ITMs/ETMs of the future LCGT are NOT included in the scope of this subsystem so far.

Applicable Documents

  • Optical Layout Drawing of the LCGT interferometer
  • Length Sensing doc
  • Alignment Sensing doc
  • Optical lever doc
  • CCD Monitor doc
  • Any...

Introduction

We can extract optical beams from the interferometer inside the vacuum chamber at the viewports. The optical beams are for length control scheme of the interferometer, alignment control scheme of the mirrors, optical levers for LCGT-SUS, and other monitoring devices (CCD or equivalent video cameras).

Stray lights?

General Description

  • AR coating for 1064 nm and 532 nm
  • Wedge angle

Details are described in Characteristics section.

Naming Conventions

Viewport Locations

  • BS chamber

Characteristics