= Viewports on Vacuum Chambers (at Room Temperature) = = Viewports (at Room Temperature) =
'''''Related subsystems:''''' MIR, IOO, MIF, VAC, CRY, VIS...
Line 11: Line 12:
== Introduction ==
We can extract optical beams from the interferometer inside the vacuum chamber at the viewports.
The optical beams are for length control scheme of the interferometer, alignment control scheme of the mirrors, optical lever for LCGT-SUS, and other monitoring devices (CCD or equivalents).

=== Applicable Documents ===
== Applicable Documents ==
 * Spec. for vacuum chambers
 * Optical Layout Drawing of the LCGT interferometer
Line 22: Line 21:
=== Definitions === == General Description ==
We can extract optical beams at the viewports from the interferometer inside the vacuum chamber.
The optical beams are for length control scheme of the interferometer, alignment control scheme of the mirrors, optical levers for LCGT-SUS, and other monitoring devices (CCD or equivalent video cameras).

Daming stray lights?

 * AR coating for 1064 nm and 532 nm
 * Wedge angle
Details are described in ''Characteristics'' section.
Line 25: Line 32:
== General Description == === Functions ===
 * Photocal
 * Optical Lever
 * Video camera
 * Illumination
 * Diagnostic
 * Squeeze
 * Spare
Line 27: Line 41:
== Naming Conventions == === Naming Conventions ===
Line 29: Line 43:
== Viewport Locations == === Locations ===
 * BS chamber
 *

== Characteristics ==

== Inspection plans ==

Viewports (at Room Temperature)

Related subsystems: MIR, IOO, MIF, VAC, CRY, VIS...


Scope

This subsystem provides the optical viewports to pass through the optical beams from the vacuum chambers in which LCGT main interferometer is stored. The optical beams include...

The viewport subsystems that will be applied to the cryo-vacuum chambers for ITMs/ETMs of the future LCGT are NOT included in the scope of this subsystem so far.

Applicable Documents

  • Spec. for vacuum chambers
  • Optical Layout Drawing of the LCGT interferometer
  • Length Sensing doc
  • Alignment Sensing doc
  • Optical lever doc
  • CCD Monitor doc
  • Any...

General Description

We can extract optical beams at the viewports from the interferometer inside the vacuum chamber. The optical beams are for length control scheme of the interferometer, alignment control scheme of the mirrors, optical levers for LCGT-SUS, and other monitoring devices (CCD or equivalent video cameras).

Daming stray lights?

  • AR coating for 1064 nm and 532 nm
  • Wedge angle

Details are described in Characteristics section.

Functions

  • Photocal
  • Optical Lever
  • Video camera
  • Illumination
  • Diagnostic
  • Squeeze
  • Spare

Naming Conventions

Locations

  • BS chamber

Characteristics

Inspection plans

LCGT/subgroup/AOS/Viewport1 (last edited 2012-09-16 20:40:35 by KiwamuIzumi)