2386
Comment:
|
3719
|
Deletions are marked like this. | Additions are marked like this. |
Line 15: | Line 15: |
==== VPZ100Q ==== | ==== VPZ100Q (ICF152) ==== |
Line 25: | Line 25: |
||0008 ||(Not yet checked?? "sonota")|| | ||0008 ||Leaking; was once installed '''IXC''', returned in advanced, and checked at the company|| |
Line 31: | Line 31: |
||0014 ||(Not yet checked.)|| ||0015 ||(Not yet checked.)|| |
||0014 ||Not yet checked; was once installed '''EXA''', preserved at the side of IMC|| ||0015 ||Not yet checked; was once installed '''EXA''', preserved at the side of IMC|| |
Line 34: | Line 34: |
||0017 ||(Not yet checked.)|| | ||0017 ||Not yet checked nor opened; preserved at the side of IMC|| |
Line 36: | Line 36: |
||0019 ||(Not yet checked.)|| ||0020 ||(Not yet checked.)|| ||0021 ||(Not yet checked.)|| ||0022 ||(Not yet checked.)|| ||0023 ||(Not yet checked.)|| ||0024 ||(Not yet checked.)|| ||0025 ||(Not yet checked.)|| ||0026 ||(Not yet checked.)|| ||0027 ||(Not yet checked.)|| ||0028 ||(Not yet checked?? "sonota")|| ||0029 ||(Not yet checked.)|| |
||0019 ||'''MCE''', Leaking (20170303)|| ||0020 ||'''MCF''', Leaking (20170303)|| ||0021 ||'''PR3''', Not yet checked.|| ||0022 ||'''MCE''', No Leak detected (20170303)|| ||0023 ||Preserved in a desiccator at PSL room, for some reasons, not yet checked.|| ||0024 ||'''MCF''', No Leak detected (20170303)|| ||0025 ||Not yet checked; was once '''EYA'''; preserved at the side of IMC.|| ||0026 ||'''BS''', not yet checked.|| ||0027 ||'''BS''', not yet checked.|| ||0028 ||Leaking; was once installed '''EYC''' probably, returned in advanced, and checked at the company|| ||0029 ||Not yet checked; was once '''EYA'''; preserved at the side of IMC.|| |
Line 52: | Line 52: |
||0035 ||(Not yet checked?? "sonota")|| | ||0035 ||Leaking; was once installed '''EYC''' probably, returned in advanced, and checked at the company|| |
Line 56: | Line 56: |
||0039 ||(Not yet checked.)|| | ||0039 ||(Not yet checked.)... but I found an empty box labeled 0039 at EXA, so there could be anywhere.|| |
Line 58: | Line 58: |
||0041 ||(Not yet checked.)|| | ||0041 ||'''IMM''', not yet checked.|| |
Line 62: | Line 62: |
==== VPZ38Q (ICF70) ==== ||Serial#||Status|| ||001 ||Leaking; was once installed '''IXA'''|| ||002 ||Leaking; was once installed '''IXA'''|| ||003 ||'''PR3''', not yet checked.|| ||004 ||Leaking, but preserved in the tunnel|| ||005 ||Leaking, but preserved in the tunnel|| ||006 ||Leaking, but preserved in the tunnel|| ||007 ||Leaking, but preserved in the tunnel; was once installed '''EYA''', and leak detected|| ||008 ||Leaking, but preserved in the tunnel; was once installed '''EYA''', and leak detected|| ||009 ||Leaking, but preserved in the tunnel|| ||010 ||No leak ''probably''; stocked at the side of IMC.|| |
Viewport windows for optical lever
Related subgroups: IOO, MIF, VAC, CRY, VIS...
Scope
- Scope...
Oplev viewport windows
FY2013 version
VPZ100Q (ICF152)
Serial# |
Status |
0000 |
Leaking, but preserved in the tunnel |
0001 |
Leaking, but preserved in the tunnel |
0002 |
(Not yet checked.) |
0003 |
(Not yet checked.) |
0004 |
(Not yet checked.) |
0005 |
Leaking, get back to the retailer (20170130) |
0006 |
Leaking, get back to the retailer (20170130) |
0007 |
Leaking, but preserved in the tunnel |
0008 |
Leaking; was once installed IXC, returned in advanced, and checked at the company |
0009 |
No leak; stocked at the side of IMC. |
0010 |
No leak; stocked at the side of IMC. |
0011 |
No leak; stocked at the side of IMC. |
0012 |
No leak; stocked at the side of IMC. |
0013 |
No leak; stocked at the side of IMC. |
0014 |
Not yet checked; was once installed EXA, preserved at the side of IMC |
0015 |
Not yet checked; was once installed EXA, preserved at the side of IMC |
0016 |
Leaking, get back to the retailer (20170130) |
0017 |
Not yet checked nor opened; preserved at the side of IMC |
0018 |
Leaking, get back to the retailer (20170130) |
0019 |
MCE, Leaking (20170303) |
0020 |
MCF, Leaking (20170303) |
0021 |
PR3, Not yet checked. |
0022 |
MCE, No Leak detected (20170303) |
0023 |
Preserved in a desiccator at PSL room, for some reasons, not yet checked. |
0024 |
MCF, No Leak detected (20170303) |
0025 |
Not yet checked; was once EYA; preserved at the side of IMC. |
0026 |
BS, not yet checked. |
0027 |
BS, not yet checked. |
0028 |
Leaking; was once installed EYC probably, returned in advanced, and checked at the company |
0029 |
Not yet checked; was once EYA; preserved at the side of IMC. |
0030 |
Leaking, get back to the retailer (20170130) |
0031 |
Reverse pressured. |
0032 |
Leaking, get back to the retailer (20170130) |
0033 |
Leaking, get back to the retailer (20170130) |
0034 |
Leaking, get back to the retailer (20170130) |
0035 |
Leaking; was once installed EYC probably, returned in advanced, and checked at the company |
0036 |
Leaking, get back to the retailer (20170130) |
0037 |
Leaking, get back to the retailer (20170130) |
0038 |
Reverse pressured. |
0039 |
(Not yet checked.)... but I found an empty box labeled 0039 at EXA, so there could be anywhere. |
0040 |
Leaking, get back to the retailer (20170130) |
0041 |
IMM, not yet checked. |
0042 |
Reverse pressured. |
...Why 43 viewport windows? Probably some serial numbers are skipped when these were delivered... Actually 40 viewport windows were purchased.
VPZ38Q (ICF70)
Serial# |
Status |
001 |
Leaking; was once installed IXA |
002 |
Leaking; was once installed IXA |
003 |
PR3, not yet checked. |
004 |
Leaking, but preserved in the tunnel |
005 |
Leaking, but preserved in the tunnel |
006 |
Leaking, but preserved in the tunnel |
007 |
Leaking, but preserved in the tunnel; was once installed EYA, and leak detected |
008 |
Leaking, but preserved in the tunnel; was once installed EYA, and leak detected |
009 |
Leaking, but preserved in the tunnel |
010 |
No leak probably; stocked at the side of IMC. |