2778
Comment:
|
3500
|
Deletions are marked like this. | Additions are marked like this. |
Line 15: | Line 15: |
==== VPZ100Q ==== | ==== VPZ100Q (ICF152) ==== |
Line 17: | Line 17: |
||0000 ||Leaking, get back to the retailer (20170130)|| ||0001 ||Leaking, get back to the retailer (20170130)|| ||0002 ||Leaking, get back to the retailer (20170130)|| ||0003 ||Leaking, get back to the retailer (20170130)|| ||0004 ||Leaking, get back to the retailer (20170130)|| |
||0000 ||Leaking, but preserved in the tunnel|| ||0001 ||Leaking, but preserved in the tunnel|| ||0002 ||(Not yet checked.) || ||0003 ||(Not yet checked.) || ||0004 ||(Not yet checked.)|| |
Line 24: | Line 24: |
||0007 ||Leaking, get back to the retailer (20170130)|| ||0008 ||Leaking, get back to the retailer (20170130)|| ||0009 ||Leaking, get back to the retailer (20170130)|| ||0010 ||Leaking, get back to the retailer (20170130)|| ||0011 ||Leaking, get back to the retailer (20170130)|| ||0012 ||Leaking, get back to the retailer (20170130)|| ||0013 ||Leaking, get back to the retailer (20170130)|| ||0014 ||Leaking, get back to the retailer (20170130)|| ||0015 ||Leaking, get back to the retailer (20170130)|| |
||0007 ||Leaking, but preserved in the tunnel|| ||0008 ||Leaking; was once installed '''IXC''', returned in advanced, and checked at the company|| ||0009 ||No leak; stocked at the side of IMC.|| ||0010 ||No leak; stocked at the side of IMC.|| ||0011 ||No leak; stocked at the side of IMC.|| ||0012 ||No leak; stocked at the side of IMC.|| ||0013 ||No leak; stocked at the side of IMC.|| ||0014 ||(Not yet checked.)|| ||0015 ||(Not yet checked.)|| |
Line 34: | Line 34: |
||0017 ||Leaking, get back to the retailer (20170130)|| | ||0017 ||(Not yet checked.)|| |
Line 36: | Line 36: |
||0019 ||Leaking, get back to the retailer (20170130)|| ||0020 ||Leaking, get back to the retailer (20170130)|| ||0021 ||Leaking, get back to the retailer (20170130)|| ||0022 ||Leaking, get back to the retailer (20170130)|| ||0023 ||Leaking, get back to the retailer (20170130)|| ||0024 ||Leaking, get back to the retailer (20170130)|| ||0025 ||Leaking, get back to the retailer (20170130)|| ||0026 ||Leaking, get back to the retailer (20170130)|| ||0027 ||Leaking, get back to the retailer (20170130)|| ||0028 ||Leaking, get back to the retailer (20170130)|| ||0029 ||Leaking, get back to the retailer (20170130)|| |
||0019 ||'''MCE''', Leaking (20170303)|| ||0020 ||'''MCF''', Leaking (20170303)|| ||0021 ||'''PR3''', Not yet checked.|| ||0022 ||'''MCE''', No Leak detected (20170303)|| ||0023 ||Preserved in a desiccator at PSL room, for some reasons, not yet checked.|| ||0024 ||'''MCF''', No Leak detected (20170303)|| ||0025 ||Not yet checked; was once '''EYA'''; preserved at the side of IMC.|| ||0026 ||'''BS''', not yet checked.|| ||0027 ||'''BS''', not yet checked.|| ||0028 ||Leaking; was once installed '''EYC''' probably, returned in advanced, and checked at the company|| ||0029 ||Not yet checked; was once '''EYA'''; preserved at the side of IMC.|| |
Line 48: | Line 48: |
||0031 ||Leaking, get back to the retailer (20170130)|| | ||0031 ||Reverse pressured.|| |
Line 52: | Line 52: |
||0035 ||Leaking, get back to the retailer (20170130)|| | ||0035 ||Leaking; was once installed '''EYC''' probably, returned in advanced, and checked at the company|| |
Line 55: | Line 55: |
||0038 ||Leaking, get back to the retailer (20170130)|| ||0039 ||Leaking, get back to the retailer (20170130)|| |
||0038 ||Reverse pressured.|| ||0039 ||(Not yet checked.)|| |
Line 58: | Line 58: |
||0041 ||'''IMM''', not yet checked.|| ||0042 ||Reverse pressured.|| ...Why 43 viewport windows? Probably some serial numbers are skipped when these were delivered... Actually 40 viewport windows were purchased. ==== VPZ38Q (ICF70) ==== ||Serial#||Status|| ||0001 ||Leaking; was once installed '''IXA'''|| ||0002 ||Leaking; was once installed '''IXA'''|| ||0003 ||'''PR3''', not yet checked.|| ||0004 ||Leaking, but preserved in the tunnel|| ||0005 ||Leaking, but preserved in the tunnel|| ||0006 ||Leaking, but preserved in the tunnel|| ||0007 ||Leaking, but preserved in the tunnel; was once installed '''EYA''', and leak detected|| ||0008 ||Leaking, but preserved in the tunnel; was once installed '''EYA''', and leak detected|| ||0009 ||Leaking, but preserved in the tunnel|| ||0010 ||No leak ''probably''; stocked at the side of IMC.|| |
Viewport windows for optical lever
Related subgroups: IOO, MIF, VAC, CRY, VIS...
Scope
- Scope...
Oplev viewport windows
FY2013 version
VPZ100Q (ICF152)
Serial# |
Status |
0000 |
Leaking, but preserved in the tunnel |
0001 |
Leaking, but preserved in the tunnel |
0002 |
(Not yet checked.) |
0003 |
(Not yet checked.) |
0004 |
(Not yet checked.) |
0005 |
Leaking, get back to the retailer (20170130) |
0006 |
Leaking, get back to the retailer (20170130) |
0007 |
Leaking, but preserved in the tunnel |
0008 |
Leaking; was once installed IXC, returned in advanced, and checked at the company |
0009 |
No leak; stocked at the side of IMC. |
0010 |
No leak; stocked at the side of IMC. |
0011 |
No leak; stocked at the side of IMC. |
0012 |
No leak; stocked at the side of IMC. |
0013 |
No leak; stocked at the side of IMC. |
0014 |
(Not yet checked.) |
0015 |
(Not yet checked.) |
0016 |
Leaking, get back to the retailer (20170130) |
0017 |
(Not yet checked.) |
0018 |
Leaking, get back to the retailer (20170130) |
0019 |
MCE, Leaking (20170303) |
0020 |
MCF, Leaking (20170303) |
0021 |
PR3, Not yet checked. |
0022 |
MCE, No Leak detected (20170303) |
0023 |
Preserved in a desiccator at PSL room, for some reasons, not yet checked. |
0024 |
MCF, No Leak detected (20170303) |
0025 |
Not yet checked; was once EYA; preserved at the side of IMC. |
0026 |
BS, not yet checked. |
0027 |
BS, not yet checked. |
0028 |
Leaking; was once installed EYC probably, returned in advanced, and checked at the company |
0029 |
Not yet checked; was once EYA; preserved at the side of IMC. |
0030 |
Leaking, get back to the retailer (20170130) |
0031 |
Reverse pressured. |
0032 |
Leaking, get back to the retailer (20170130) |
0033 |
Leaking, get back to the retailer (20170130) |
0034 |
Leaking, get back to the retailer (20170130) |
0035 |
Leaking; was once installed EYC probably, returned in advanced, and checked at the company |
0036 |
Leaking, get back to the retailer (20170130) |
0037 |
Leaking, get back to the retailer (20170130) |
0038 |
Reverse pressured. |
0039 |
(Not yet checked.) |
0040 |
Leaking, get back to the retailer (20170130) |
0041 |
IMM, not yet checked. |
0042 |
Reverse pressured. |
...Why 43 viewport windows? Probably some serial numbers are skipped when these were delivered... Actually 40 viewport windows were purchased.
VPZ38Q (ICF70)
Serial# |
Status |
0001 |
Leaking; was once installed IXA |
0002 |
Leaking; was once installed IXA |
0003 |
PR3, not yet checked. |
0004 |
Leaking, but preserved in the tunnel |
0005 |
Leaking, but preserved in the tunnel |
0006 |
Leaking, but preserved in the tunnel |
0007 |
Leaking, but preserved in the tunnel; was once installed EYA, and leak detected |
0008 |
Leaking, but preserved in the tunnel; was once installed EYA, and leak detected |
0009 |
Leaking, but preserved in the tunnel |
0010 |
No leak probably; stocked at the side of IMC. |