Viewport windows for optical lever
Related subgroups: IOO, MIF, VAC, CRY, VIS...
Scope
- Scope...
Oplev viewport windows
FY2013 version
VPZ100Q (ICF152)
Serial# |
Status |
0000 |
Leaking, but preserved in the tunnel |
0001 |
Leaking, but preserved in the tunnel |
0002 |
(Not yet checked.) |
0003 |
(Not yet checked.) |
0004 |
(Not yet checked.) |
0005 |
Leaking, get back to the retailer (20170130) |
0006 |
Leaking, get back to the retailer (20170130) |
0007 |
Leaking, but preserved in the tunnel |
0008 |
Leaking; was once installed IXC, returned in advanced, and checked at the company |
0009 |
No leak; stocked at the side of IMC. |
0010 |
No leak; stocked at the side of IMC. |
0011 |
No leak; stocked at the side of IMC. |
0012 |
No leak; stocked at the side of IMC. |
0013 |
No leak; stocked at the side of IMC. |
0014 |
Not yet checked; was once installed EXA, preserved at the side of IMC |
0015 |
Not yet checked; was once installed EXA, preserved at the side of IMC |
0016 |
Leaking, get back to the retailer (20170130) |
0017 |
Not yet checked nor opened; preserved at the side of IMC |
0018 |
Leaking, get back to the retailer (20170130) |
0019 |
MCE, Leaking (20170303) |
0020 |
MCF, Leaking (20170303) |
0021 |
PR3, Not yet checked. |
0022 |
MCE, No Leak detected (20170303) |
0023 |
Preserved in a desiccator at PSL room, for some reasons, not yet checked. |
0024 |
MCF, No Leak detected (20170303) |
0025 |
Not yet checked; was once EYA; preserved at the side of IMC. |
0026 |
BS, not yet checked. |
0027 |
BS, not yet checked. |
0028 |
Leaking; was once installed EYC probably, returned in advanced, and checked at the company |
0029 |
Not yet checked; was once EYA; preserved at the side of IMC. |
0030 |
Leaking, get back to the retailer (20170130) |
0031 |
Reverse pressured. |
0032 |
Leaking, get back to the retailer (20170130) |
0033 |
Leaking, get back to the retailer (20170130) |
0034 |
Leaking, get back to the retailer (20170130) |
0035 |
Leaking; was once installed EYC probably, returned in advanced, and checked at the company |
0036 |
Leaking, get back to the retailer (20170130) |
0037 |
Leaking, get back to the retailer (20170130) |
0038 |
Reverse pressured. |
0039 |
(Not yet checked.)... but I found an empty box at EXA, so there could be anywhere. |
0040 |
Leaking, get back to the retailer (20170130) |
0041 |
IMM, not yet checked. |
0042 |
Reverse pressured. |
...Why 43 viewport windows? Probably some serial numbers are skipped when these were delivered... Actually 40 viewport windows were purchased.
VPZ38Q (ICF70)
Serial# |
Status |
0001 |
Leaking; was once installed IXA |
0002 |
Leaking; was once installed IXA |
0003 |
PR3, not yet checked. |
0004 |
Leaking, but preserved in the tunnel |
0005 |
Leaking, but preserved in the tunnel |
0006 |
Leaking, but preserved in the tunnel |
0007 |
Leaking, but preserved in the tunnel; was once installed EYA, and leak detected |
0008 |
Leaking, but preserved in the tunnel; was once installed EYA, and leak detected |
0009 |
Leaking, but preserved in the tunnel |
0010 |
No leak probably; stocked at the side of IMC. |