335
Comment:
|
1430
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
= To complete IMC for O4 = | = Upgrade IMC for O4 = |
Line 4: | Line 4: |
||<<MonthCalendar(,2021,1)>>||<<MonthCalendar(,2021,2)>>||<<MonthCalendar(,2021,3)>>|| ||<<MonthCalendar(,2021,4)>>|| || || |
||<<MonthCalendar(,2021,2)>>||<<MonthCalendar(,2021,3)>>||<<MonthCalendar(,2021,4)>>|| ||<<MonthCalendar(,2021,5)>>|| || || |
Line 9: | Line 9: |
* xxx | * Slack channel: #imc-upgrade * Beam position on the shield of the IMC Type-C: [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12114]] * IMC Type-C shield install procedure: [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12382]] * Installing the shields and BeamDumps for IMC [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11636]] |
Line 18: | Line 21: |
* xxx | * Attach black shielding around the MCi, MCo, and MCe suspensions for mitigate stray light * Relocate the connector plates of these suspensions. * Tame the electric wires from the coil bobbins. * Put beam dumps in the MCE and MCF chambers. * Confirm the position of POM1 * Attach the beam dump to POM1 * Confirm the position of a mirror (and the size) for MCo oplev * Confirm each suspension can work very well (acceptance test) * Alignment sensing control. * Confirm no clipping of the beams. * Confirm the laser beams are not hitting strange things such as coil wires and so on. * Make the final 3D model inside of the MCF and MCE chambers before closing them. |
Upgrade IMC for O4
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
Links to knowledge
- Slack channel: #imc-upgrade
Beam position on the shield of the IMC Type-C: https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12114
IMC Type-C shield install procedure: https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12382
Installing the shields and BeamDumps for IMC https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11636
Related areas
MCF, MCE
Task list
Note: some of the tasks can be done in parallel.
- Attach black shielding around the MCi, MCo, and MCe suspensions for mitigate stray light
- Relocate the connector plates of these suspensions.
- Tame the electric wires from the coil bobbins.
- Put beam dumps in the MCE and MCF chambers.
- Confirm the position of POM1
- Attach the beam dump to POM1
- Confirm the position of a mirror (and the size) for MCo oplev
- Confirm each suspension can work very well (acceptance test)
- Alignment sensing control.
- Confirm no clipping of the beams.
- Confirm the laser beams are not hitting strange things such as coil wires and so on.
- Make the final 3D model inside of the MCF and MCE chambers before closing them.