Electronic Boxes BS Rack
* BS Suspension Electronic Items List
Type of box |
Number |
Box Name |
Used for |
Link to JGW |
ADC |
D1100621 |
ADC#0 |
BS in general |
- |
ADC#1 |
BS in general |
- |
||
DAC |
D1100650 |
DAC#0 |
BS in general |
- |
DAC#1 |
BS in general |
- |
||
LPCD |
D1503506 |
LPCD#0 |
TM OSEMs |
- |
LPCD#1 |
IM OSEMs |
- |
||
LPCD#2 |
IM OSEMs |
- |
||
HPCD |
D1503502 |
HPCD#0 |
BF GAS, SF GAS, F0 GAS |
- |
HPCD#1 |
PI LVDT#0, PI LVDT#1, PI LVDT#2 |
- |
||
Geophone Distributor |
D1402120 |
GEO |
GEO#0, GEO#1, GEO#2 |
- |
LVDT Driver |
D |
LVDT Driver |
GAS, PI LVDT |
- |
LVDT-ACT Distributor |
D402124 |
LVDT-ACT Distributor |
GAS, PI LVDT |
- |
Hub |
D |
Hub |
Stepper Motor Drivers, Pico Motor Drivers |
- |
Electronic Boxes BS Clean booth
* BS Suspension Electronic Items List
Type of box |
Number |
Box Name |
Used for |
Serial Number |
IP Address |
Link to JGW |
Satellite Amplifier |
D |
SA#0 |
TM OSEMs |
S1503811 |
- |
- |
SA#1 |
IM OSEMs |
S1504431 |
- |
- |
||
SA#2 |
IM OSEMs |
S1504441 |
- |
- |
||
Stepper Motor Driver |
D |
Stepper Motor Driver #0 |
BF Stepper, SF Stepper |
S1606032 |
10.68.150.50 |
- |
Stepper Motor Driver #1 |
PI Stepper#0, PI Stepper#1, PI Stepper#2, V F0 Stepper, Y F0 Stepper |
S1606032 |
10.68.150.51 |
- |
||
Pico Motor Driver |
D |
Pico Motor Driver#0 |
IM Picos ("BS-IM") |
S1504931 |
10.68.150.16 |
- |
Pico Motor Driver#1 |
BF Picos ("BS-BF") |
S1505766 |
10.68.150.17 |
- |
In Air Cables
Location and Type |
Name |
20[m] D-Sub 9 |
20[m] D-Sub 15 |
1[m] D-Sub 9 |
2[m] D-Sub 9 |
1.5[m] D-Sub 37 |
2[m] D-Sub 9 to D-sub 15 |
Comp Cable (white) |
CNA/CNB Cable (black) |
xx [m] LAN |
xx[m] Power +-18V |
From Rack to Clean booth |
SA#0 Coil |
- |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
SA#1 Coil |
- |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
|
SA#2 Coil |
- |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
|
SA#0 PD |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
SA#1 PD |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
SA#2 PD |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
BF LVDT |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
SF LVDT |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
F0 LVDT |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
PI LVDT#0 |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
PI LVDT#1 |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
PI LVDT#2 |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
GEO#0 |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
GEO#1 |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
GEO#2 |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
Pico Motor Driver #0 |
- |
- |
- |
- |
- |
- |
- |
- |
1 |
- |
|
Pico Motor Driver #1 |
- |
- |
- |
- |
- |
- |
- |
- |
1 |
- |
|
Stepper Motor Driver #0 |
- |
- |
- |
- |
- |
- |
- |
- |
1 |
1 |
|
Stepper Motor Driver #1 |
- |
- |
- |
- |
- |
- |
- |
- |
1 |
1 |
|
OpLev Tilt |
- |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
|
OpLev Length |
- |
1 |
- |
- |
- |
- |
- |
- |
- |
- |
|
At the Rack |
LPCD#0 to DAC#0 (OSEM#0) |
- |
- |
1 |
- |
- |
- |
- |
- |
- |
- |
LPCD#1 to DAC#0 (OSEM#1) |
- |
- |
1 |
- |
- |
- |
- |
- |
- |
- |
|
LPCD#2 to DAC#0 (OSEM#2) |
- |
- |
1 |
- |
- |
- |
- |
- |
- |
- |
|
HPCD#0 to DAC#0 (PI LVDT) |
- |
- |
1 |
- |
- |
- |
- |
- |
- |
- |
|
HPCD#1 to DAC#0 (GAS) |
- |
- |
- |
1 |
- |
- |
- |
- |
- |
- |
|
LVDT Distributor to LVDT Driver |
- |
- |
4 |
- |
- |
- |
- |
- |
- |
- |
|
LPCD#0 to PCIe I/O |
- |
- |
- |
- |
2 |
- |
- |
2 |
- |
- |
|
LPCD#1 to PCIe I/O |
- |
- |
- |
- |
2 |
- |
- |
2 |
- |
- |
|
LPCD#2 to PCIe I/O |
- |
- |
- |
- |
2 |
- |
- |
2 |
- |
- |
|
HPCD#0 to PCIe I/O |
- |
- |
- |
- |
2 |
- |
- |
2 |
- |
- |
|
HPCD#1 to PCIe I/O |
- |
- |
- |
- |
2 |
- |
- |
2 |
- |
- |
|
DAC#0 to PCIe I/O |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
- |
|
DAC#1 to PCIe I/O |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
- |
|
ADC#0 to PCIe I/O |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
- |
|
ADC#1 to PCIe I/O |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
- |
|
LVDT Driver to HPCD#0 |
- |
- |
- |
- |
- |
1 |
- |
- |
- |
- |
|
LVDT Driver to HPCD#1 |
- |
- |
- |
- |
- |
1 |
- |
- |
- |
- |
|
Inside Clean booth |
Extension 1 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
Extension 2 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
Extension 3 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
Total |
Total |
12 |
5 |
8 |
1 |
10 |
2 |
4 |
10 |
4 |
2 |
In Vacuum cables used in the BS suspension
Device |
Type 5 - 2.2 m |
Type 5 - 2.4 m |
Type 5 - 1.7 m |
Type 3 - 4 m |
Type 3 - 2 m |
Type 4 - 4 m |
Type 4 - 2 m |
Type 1 |
Type 1 - 2 m |
Type 2 - 2 m |
Gender changer |
OSEM TM-H1 |
1 |
- |
- |
1 |
- |
- |
- |
- |
- |
- |
1 |
OSEM TM-H2 |
- |
1 |
- |
1 |
- |
- |
- |
- |
- |
- |
1 |
OSEM TM-H3 |
- |
1 |
- |
1 |
- |
- |
- |
- |
- |
- |
1 |
OSEM TM-H4 |
1 |
- |
- |
1 |
- |
- |
- |
- |
- |
- |
1 |
OSEM IM-H1 |
- |
- |
1 |
1 |
- |
- |
- |
- |
- |
- |
1 |
OSEM IM-H2 |
- |
- |
1 |
1 |
- |
- |
- |
- |
- |
- |
1 |
OSEM IM-H3 |
- |
- |
1 |
1 |
- |
- |
- |
- |
- |
- |
1 |
OSEM IM-V1 |
- |
- |
1 |
1 |
- |
- |
- |
- |
- |
- |
1 |
OSEM IM-V2 |
- |
- |
1 |
1 |
- |
- |
- |
- |
- |
- |
1 |
OSEM IM-V3 |
- |
- |
1 |
1 |
- |
- |
- |
- |
- |
- |
1 |
IM Pico Motor |
- |
- |
- |
- |
- |
1 |
- |
- |
- |
- |
1 |
BF Pico Motor |
- |
- |
- |
- |
- |
1 |
- |
- |
- |
- |
1 |
BF Stepper Motor |
- |
- |
- |
- |
- |
1 |
- |
- |
- |
- |
1 |
SF Stepper Motor |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
- |
- |
BF LVDT |
- |
- |
- |
1 |
- |
- |
- |
- |
- |
- |
1 |
SF LVDT |
- |
- |
- |
1 |
- |
- |
- |
- |
- |
- |
1 |
F0 LVDT |
- |
- |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
PI LVDT # 0 |
- |
- |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
PI LVDT # 1 |
- |
- |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
PI LVDT # 2 |
- |
- |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
PI Stepper Motor # 0 |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
- |
- |
PI Stepper Motor # 1 |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
- |
- |
PI Stepper Motor # 2 |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
- |
- |
PI Vertical-Yaw Stepper Motor |
- |
- |
- |
- |
- |
- |
- |
- |
- |
1 |
- |
PI Geophone # 0 |
- |
- |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
PI Geophone # 1 |
- |
- |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
PI Geophone # 2 |
- |
- |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
Total |
2 |
2 |
6 |
12 |
0 |
3 |
4 |
0 |
7 |
1 |
15 |
Cables not used inside BS clean booth
Cable |
Type 1-2 m |
Type 2-2 m |
Type 3-1.5 m |
Type 3-2 m |
Type 3-4 m |
Type 4-1 m |
Type 4-1.5 m |
Type 4-2 m |
Type 4-4 |
Type 5-1.7 m |
Type 5-2 m |
Type 5-2.2 m |
Type 5-2.4 m |
Gender changer |
Total |
0 |
5 |
7 |
1 |
3 |
1 |
3 |
0 |
0 |
1 |
3 |
0 |
0 |
0 |
Connections
Under preparation:
cell spanning 2 rows |
cell in the 2nd column |
|||
cell in the 2nd column of the 2nd row |
||||
Box Name |
N. Conectors or Channels |
cell spanning 3 columns |
Box Name |
N. Conectors or Channels |
Channel Used |
Connected to |
In-air cabling |
ADC#0 |
8 Channels |
#0-3 |
SA#0 |
Done |
#4-7 |
SA#1 |
Done |
||
#8-11 |
SA#2 |
Done |
||
#12-15 |
GAS |
- |
||
#16-19 |
IP LVDT |
- |
||
#20-23 |
IP GEO |
- |
||
#24-27 |
OL-T |
- |
||
#28-31 |
- |
- |
||
use empty cells as a shorthand |
Box Name |
N. Conectors or Channels |
Channel Used |
Connected to |
In-air cabling |
LPCD#0 |
4 Front 5 Back |
Coil 0ut to Sat |
SA#0 |
Done |
LPCD#1 |
4 Front 5 Back |
Coil 0ut to Sat |
SA#1 |
Done |
LPCD#2 |
4 Front 5 Back |
Coil 0ut to Sat |
SA#2 |
Done |
use empty cells as a shorthand |