668
Comment:
|
2288
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
= Auxiliary Optics Subsystem (AOS) = | = LCGT Auxiliary Optics Subsystem (AOS) = |
Line 3: | Line 3: |
<<TableOfContents(3)>> | <<TableOfContents(2)>> |
Line 6: | Line 6: |
of the subgroup "Auxiliary Optics System" is to have the other LCGT subgroups design and complete the auxiliary optics that physically, logically and consistently glue many parts of the LCGT interferometer. | The objectives of the subgroup "Auxiliary Optics System" is to have the other LCGT subgroups design and complete the auxiliary optics that physically, logically and consistently glue the main parts of the LCGT interferometer together. |
Line 8: | Line 8: |
== References and Links == ||[[LCGT/Terminology|Terminology]] ||[[LCGT/subgroup/vacuum|Layout Meeting]]|| ||[[LCGT/subgroup/ifo/MIF/AuxOpticsLists|Aux. opt. list from MIF's point of view]] ||[[LCGT/subgroup/OCG/parametermeeting|Parameter Meeting]]|| ||[[LCGT/iLCGT/IFOParameters|Optical Parameters]] || |
== General Description == All the AOS shall be fit to the vacuum chambers that had been already determined when the AOS group was established. Even if the vacuum chamber was not designed for considering the space allocated for AOS, AOS are required for fully operating LCGT, so we should pack them into the vacuum chambers '''''BY ANY MEANS'''''. == References == ||[[LCGT/subgroup/ifo/MIF/AuxOpticsLists|Aux. opt. list from MIF's point of view]]||[[LCGT/subgroup/vacuum|Layout Meeting]]|| || ||[[LCGT/subgroup/ifo/MIF/OptParam|Optical Parameters]]||[[LCGT/subgroup/OCG/parametermeeting|Parameter Meeting]]|| || ||[[LCGT/SVN|LCGT SVN]] ||[[LCGT/Terminology|Terminology]]||[[LCGT/iLCGT/Subgroup/DiscussionRana2010 | Discussion with Rana 2010]]|| == Subsystems == * [[LCGT/subgroup/AOS/StrayLight1|Stray Light Control]] * [[LCGT/subgroup/AOS/BeamReduceTelescope1|Transmit Telescopes (transmit IR/Green beams)]] * [[LCGT/subgroup/AOS/StrayLight2|Output Faraday Isolaters]] * [[LCGT/subgroup/AOS/OptLev1|Optical Lever]] * [[LCGT/subgroup/AOS/CCD1|CCD monitors]] * [[LCGT/subgroup/AOS/Viewport1|Viewports on Vacuum Chambers]] * [[LCGT/subgroup/AOS/InitialAlign1|Initial Alignment Setting]] * [[LCGT/subgroup/AOS/JBOSEM1|Local Sensors and Actuators (LIGO's OSEM-like things utilized in vibration isolation system)]] * [[LCGT/subgroup/AOS/Violine1|Violine mode sensors or Wire position sensors (utilized in vibration isolation system or in noise-hunting phase)]] * Other local sensors/monitors/actuators? * Squeezing system?? * [[LCGT/subgroup/AOS/Shutter1|Beam Shutter]] * [[LCGT/subgroup/AOS/Optics1|Any other optics, outside breadboard,... ]] * [[LCGT/subgroup/AOS/Mirror1|Micro Roughness of Mirrors]] == Meetings == * [[LCGT/subgroup/AOS/Meetings|LCGT-AOS Meetings]] |
Line 14: | Line 37: |
== Meetings == [[LCGT/subgroup/AOS/Meetings|Meetings]] |
== Links == * [[https://dcc.ligo.org/|LIGO Document Control Center]] * [[https://www.advancedligo.mit.edu/aos.html|adv.LIGO Aux. Optics]] |
LCGT Auxiliary Optics Subsystem (AOS)
Contents
Objectives
The objectives of the subgroup "Auxiliary Optics System" is to have the other LCGT subgroups design and complete the auxiliary optics that physically, logically and consistently glue the main parts of the LCGT interferometer together.
General Description
All the AOS shall be fit to the vacuum chambers that had been already determined when the AOS group was established. Even if the vacuum chamber was not designed for considering the space allocated for AOS, AOS are required for fully operating LCGT, so we should pack them into the vacuum chambers BY ANY MEANS.
References
|
||
|
||
Subsystems
Local Sensors and Actuators (LIGO's OSEM-like things utilized in vibration isolation system)
- Other local sensors/monitors/actuators?
- Squeezing system??
Meetings