1936
Comment:
|
2288
|
Deletions are marked like this. | Additions are marked like this. |
Line 6: | Line 6: |
The objectives of the subgroup "Auxiliary Optics System" is to have the other LCGT subgroups design and complete the auxiliary optics that physically, logically and consistently glue the main parts of the LCGT interferometer together. | The objectives of the subgroup "Auxiliary Optics System" (AOS) is to have the other LCGT subgroups design and complete the auxiliary optics that physically, logically and consistently glue the main parts of the LCGT interferometer together. == General Description == All the AOS shall be fit to the vacuum chambers that had been already determined when the AOS group was established. Even if the vacuum chamber was not designed for considering the space allocated for AOS, AOS are required for fully operating LCGT, so we should pack them into the vacuum chambers '''''BY ANY MEANS'''''. |
Line 14: | Line 18: |
* [[LCGT/subgroup/AOS/StrayLight1|Stray Light Control]] * [[LCGT/subgroup/AOS/BeamReduceTelescope1|Transmit Telescopes (transmit IR/Green beams)]] * [[LCGT/subgroup/AOS/StrayLight2|Output Faraday Isolaters]] |
* [[LCGT/subgroup/AOS/StrayLight1|Stray Light Control (incl.: beam baffles, output Faraday, calc. of BRDF...)]] * [[LCGT/subgroup/AOS/BeamReduceTelescope1|IR Pick-off and transmit telescopes]] * [[LCGT/subgroup/AOS/BeamReduceTelescope2|Green Transmit Telescopes]] |
Line 18: | Line 22: |
* [[LCGT/subgroup/AOS/CCD1|CCD monitors]] * [[LCGT/subgroup/AOS/Viewport1|Viewports on Vacuum Chambers]] * [[LCGT/subgroup/AOS/InitialAlign1|Initial Alignment Setting]] |
* [[LCGT/subgroup/AOS/InitialAlign1|Initial Alignment System]] |
Line 24: | Line 26: |
* [[LCGT/subgroup/AOS/CCD1|CCD monitors]] * [[LCGT/subgroup/AOS/Viewport1|Viewports on Vacuum Chambers]] |
|
Line 27: | Line 31: |
* [[LCGT/subgroup/AOS/Mirror1|Micro Roughness of Mirrors]] |
LCGT Auxiliary Optics Subsystem (AOS)
Contents
Objectives
The objectives of the subgroup "Auxiliary Optics System" (AOS) is to have the other LCGT subgroups design and complete the auxiliary optics that physically, logically and consistently glue the main parts of the LCGT interferometer together.
General Description
All the AOS shall be fit to the vacuum chambers that had been already determined when the AOS group was established. Even if the vacuum chamber was not designed for considering the space allocated for AOS, AOS are required for fully operating LCGT, so we should pack them into the vacuum chambers BY ANY MEANS.
References
|
||
|
||
Subsystems
Stray Light Control (incl.: beam baffles, output Faraday, calc. of BRDF...)
Local Sensors and Actuators (LIGO's OSEM-like things utilized in vibration isolation system)
- Other local sensors/monitors/actuators?
- Squeezing system??
Meetings