Line 3: | Line 3: |
||<<MonthCalendar(,2018,6)>>||<<MonthCalendar(,2018,7)>>|| | ||<<MonthCalendar(,2018,6)>>||<<MonthCalendar(,2018,7)>>||<<MonthCalendar(,2018,8)>>||<<MonthCalendar(,2018,9)>>|| |
Line 21: | Line 21: |
* Place/install the WAB suspension. * Align the position of WAB -> take WAB back to nominal position, put off protectors * Blow inside the WAB; put protectors and shield the aperture (foil?) |
* --(Place/install the WAB suspension)-- * --(Align the position of WAB -> take WAB back to nominal position, put off protectors)-- * --(horizontal alignment)-- * --(yaw alignment)-- * --(Lift-up WAB by 1mm)-- * --(Blow inside the WAB; put protectors and shield the aperture (foil?))-- |
Line 27: | Line 30: |
== Pin Assignment == P22 ||Pin Name||Resistance|| Equipment || Assign || Comment1 || Comment2 || Connection || ||A||75 ohm|| Thermometer || V- || Green || || || ||B||75 ohm|| Thermometer || V+ || Black || || || ||C||4 ohm|| Thermometer || I- || Red || || || ||D||4 ohm|| Thermometer || I+ || Yellow || || || ||E||75 ohm|| Thermometer || V- || Green || || || ||F||75 ohm|| Thermometer || V+ || Black || || || ||G||4 ohm|| Thermometer || I- || Red || || || ||H||4 ohm|| Thermometer || I+ || Yellow || || || Note that the pin arrangement (or the ''naming'') is mirrored compared with that of in IYC! Rather, I guess this IXC's would be correct. |
Wide Angle Baffle at IXC
|
|
|
|
Links to knowledge
Calculations regarding the back-scattering of different Wide Angle Baffle designs (Zeidler)
Personal calc of WAB's stray light noise by Akutsu; due to several uncertain parameters there are several results and no one would know the actual effect!
Heat links positions (by Obuchi) fmkopgehpapgdkcc.png
Task list
Note: some of the tasks can be done in parallel.
Place/install the WAB suspension
Align the position of WAB -> take WAB back to nominal position, put off protectors
horizontal alignment
yaw alignment
Lift-up WAB by 1mm
Blow inside the WAB; put protectors and shield the aperture (foil?)
- Clean area around chamber
Heat-Link adapter to WAB -> Needs to be designed (Akutsu/Obuchi)
- Thermometer adapter to WAB
Pin Assignment
P22
Pin Name |
Resistance |
Equipment |
Assign |
Comment1 |
Comment2 |
Connection |
A |
75 ohm |
Thermometer |
V- |
Green |
|
|
B |
75 ohm |
Thermometer |
V+ |
Black |
|
|
C |
4 ohm |
Thermometer |
I- |
Red |
|
|
D |
4 ohm |
Thermometer |
I+ |
Yellow |
|
|
E |
75 ohm |
Thermometer |
V- |
Green |
|
|
F |
75 ohm |
Thermometer |
V+ |
Black |
|
|
G |
4 ohm |
Thermometer |
I- |
Red |
|
|
H |
4 ohm |
Thermometer |
I+ |
Yellow |
|
|
Note that the pin arrangement (or the naming) is mirrored compared with that of in IYC! Rather, I guess this IXC's would be correct.