Differences between revisions 7 and 15 (spanning 8 versions)
Revision 7 as of 2018-06-26 17:32:52
Size: 1667
Editor: SimonZeidler
Comment:
Revision 15 as of 2021-11-24 20:51:41
Size: 2577
Comment:
Deletions are marked like this. Additions are marked like this.
Line 3: Line 3:
||<<MonthCalendar(,2018,6)>>||<<MonthCalendar(,2018,7)>>|| ||<<MonthCalendar(,2018,6)>>||<<MonthCalendar(,2018,7)>>||<<MonthCalendar(,2018,8)>>||<<MonthCalendar(,2018,9)>>||
||<<MonthCalendar(,2020,11)>>||||||||
||<<MonthCalendar(,2021,11)>>||||||||
Line 22: Line 25:
 * Align the position of WAB -> take WAB back to nominal position, put off protectors
 * Blo
w inside the WAB; put protectors and shield the aperture (foil?)
 * --(Align the position of WAB -> take WAB back to nominal position, put off protectors)--
  * --(horizontal alignment)--
  * --(ya
w alignment)--
 * --(Lift-up WAB by 1mm)--
 * --(Blow
inside the WAB; put protectors and shield the aperture (foil?))--
Line 27: Line 33:

== Pin Assignment ==
P23
||Pin Name||Resistance|| Equipment || Assign || Comment1 || Comment2 || Connection ||
||A||75 ohm|| Thermometer || V- || Green || || ||
||B||75 ohm|| Thermometer || V+ || Black || || ||
||C||4 ohm|| Thermometer || I- || Red || || ||
||D||4 ohm|| Thermometer || I+ || Yellow || || ||
||E||75 ohm|| Thermometer || V- || Green || || ||
||F||75 ohm|| Thermometer || V+ || Black || || ||
||G||4 ohm|| Thermometer || I- || Red || || ||
||H||4 ohm|| Thermometer || I+ || Yellow || || ||

Note that the pin arrangement (or the ''naming'') is mirrored compared with that of in IYC! Rather, I guess this IXC's would be correct.

Wide Angle Baffle at IXC

<< <  2018 / 6 >  >>
Mon Tue Wed Thu Fri Sat Sun
        1 2 3
4 5 6 7 8 9 10
11 12 13 14 15 16 17
18 19 20 21 22 23 24
25 26 27 28 29 30  

<< <  2018 / 7 >  >>
Mon Tue Wed Thu Fri Sat Sun
            1
2 3 4 5 6 7 8
9 10 11 12 13 14 15
16 17 18 19 20 21 22
23 24 25 26 27 28 29
30 31          

<< <  2018 / 8 >  >>
Mon Tue Wed Thu Fri Sat Sun
    1 2 3 4 5
6 7 8 9 10 11 12
13 14 15 16 17 18 19
20 21 22 23 24 25 26
27 28 29 30 31    

<< <  2018 / 9 >  >>
Mon Tue Wed Thu Fri Sat Sun
          1 2
3 4 5 6 7 8 9
10 11 12 13 14 15 16
17 18 19 20 21 22 23
24 25 26 27 28 29 30

<< <  2020 / 11 >  >>
Mon Tue Wed Thu Fri Sat Sun
            1
2 3 4 5 6 7 8
9 10 11 12 13 14 15
16 17 18 19 20 21 22
23 24 25 26 27 28 29
30            

<< <  2021 / 11 >  >>
Mon Tue Wed Thu Fri Sat Sun
1 2 3 4 5 6 7
8 9 10 11 12 13 14
15 16 17 18 19 20 21
22 23 24 25 26 27 28
29 30          

Task list

Note: some of the tasks can be done in parallel.

  • Place/install the WAB suspension

  • Align the position of WAB -> take WAB back to nominal position, put off protectors

    • horizontal alignment

    • yaw alignment

  • Lift-up WAB by 1mm

  • Blow inside the WAB; put protectors and shield the aperture (foil?)

  • Clean area around chamber
  • Heat-Link adapter to WAB -> Needs to be designed (Akutsu/Obuchi)

  • Thermometer adapter to WAB

Pin Assignment

P23

Pin Name

Resistance

Equipment

Assign

Comment1

Comment2

Connection

A

75 ohm

Thermometer

V-

Green

B

75 ohm

Thermometer

V+

Black

C

4 ohm

Thermometer

I-

Red

D

4 ohm

Thermometer

I+

Yellow

E

75 ohm

Thermometer

V-

Green

F

75 ohm

Thermometer

V+

Black

G

4 ohm

Thermometer

I-

Red

H

4 ohm

Thermometer

I+

Yellow

Note that the pin arrangement (or the naming) is mirrored compared with that of in IYC! Rather, I guess this IXC's would be correct.

KAGRA/subgroup/AOS/WideAngleBaffleIX (last edited 2021-11-24 20:51:41 by TomotadaAkutsu)