2294
Comment:
|
2671
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
= LCGT Auxiliary Optics Subsystem (AOS) = | = LCGT Auxiliary Optics System (AOS) = |
Line 9: | Line 9: |
All the AOS shall be fit to the vacuum chambers that had been already determined when the AOS group was established. Even if the vacuum chamber was not designed for considering the space allocated for AOS, AOS are required for fully operating LCGT, so we should pack them into the vacuum chambers '''''BY ANY MEANS'''''. |
Most of the AOS shall be fit to the vacuum chambers that had been already determined when the AOS group was established. Even if the vacuum chamber was not designed considering the space allocated for AOS, AOS are required for fully operating LCGT, so we shall, by any means, pack them into the vacuum chambers if required. |
Line 19: | Line 19: |
* [[LCGT/subgroup/AOS/BeamReduceTelescope1|Transmit Telescopes (transmit IR/Green beams)]] * [[LCGT/subgroup/AOS/StrayLight2|Output Faraday Isolaters]] |
* <!> Including beam baffles, output Faraday isolators, and calculation of BRDF of test masses... * [[LCGT/subgroup/AOS/BeamReduceTelescope1|Beam Reducing Telescopes]] |
Line 22: | Line 22: |
* [[LCGT/subgroup/AOS/InitialAlign1|Initial Alignment Setting]] * [[LCGT/subgroup/AOS/JBOSEM1|Local Sensors and Actuators (LIGO's OSEM-like things utilized in vibration isolation system)]] * [[LCGT/subgroup/AOS/Violine1|Violine mode sensors or Wire position sensors (utilized in vibration isolation system or in noise-hunting phase)]] * Other local sensors/monitors/actuators? * [[LCGT/subgroup/AOS/CCD1|CCD monitors]] * [[LCGT/subgroup/AOS/Viewport1|Viewports on Vacuum Chambers]] |
* <!> Optical lever is a kind of local sensors, but unlike other local sensors, it requires long beam lines as lever's arms, thus this should be considerd in AOS. * [[LCGT/subgroup/AOS/CCD1|Viewing Monitors and Light Sources]] * [[LCGT/subgroup/AOS/Viewport1|Viewports]] * [[LCGT/subgroup/AOS/BeamTarget1|Automatic Target System]] * [[LCGT/subgroup/AOS/BeamModeProfiler1|Mode Profiler for huge beam]] |
Line 29: | Line 28: |
* [[LCGT/subgroup/AOS/Shutter1|Beam Shutter]] * [[LCGT/subgroup/AOS/Optics1|Any other optics, outside breadboard,... ]] * [[LCGT/subgroup/AOS/Mirror1|Micro Roughness of Mirrors]] |
* Any other optics, outside breadboard,... * Highly Related Subsystems (not included in AOS) * [[LCGT/subgroup/AOS/Shutter1|Beam Shutters]](IOO, MIF) * [[LCGT/subgroup/AOS/InitialAlign1|Initial Alignment]](MIF) * [[LCGT/subgroup/AOS/JBOSEM1|Local Sensors and Actuators (LIGO's OSEM-like things utilized in vibration isolation system)]](VIS) * [[LCGT/subgroup/AOS/Violine1|Violine mode sensors or Wire position sensors (utilized in vibration isolation system or in noise-hunting phase)]](VIS?) |
Line 40: | Line 43: |
* [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/LCGT/subgroup/howtojoin|How to join Mailing Lists for LCGT project]] |
LCGT Auxiliary Optics System (AOS)
Contents
Objectives
The objectives of the subgroup "Auxiliary Optics System" (AOS) is to have the other LCGT subgroups design and complete the auxiliary optics that physically, logically and consistently glue the main parts of the LCGT interferometer together.
General Description
Most of the AOS shall be fit to the vacuum chambers that had been already determined when the AOS group was established. Even if the vacuum chamber was not designed considering the space allocated for AOS, AOS are required for fully operating LCGT, so we shall, by any means, pack them into the vacuum chambers if required.
References
|
||
|
||
Subsystems
Including beam baffles, output Faraday isolators, and calculation of BRDF of test masses...
Optical lever is a kind of local sensors, but unlike other local sensors, it requires long beam lines as lever's arms, thus this should be considerd in AOS.
- Squeezing system??
- Any other optics, outside breadboard,...
- Highly Related Subsystems (not included in AOS)
Meetings