Size: 2800
Comment:
|
Size: 2972
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 9: | Line 9: |
All the AOS shall be fit to the vacuum chambers that had been already determined when the AOS group was established. Even if the vacuum chamber was not designed for considering the space allocated for AOS, AOS are required for fully operating LCGT, so we should pack them into the vacuum chambers by any means. |
Most of the AOS shall be fit to the vacuum chambers that had been already determined when the AOS group was established. Even if the vacuum chamber was not designed considering the space allocated for AOS, AOS are required for fully operating LCGT, so we shall, by any means, pack them into the vacuum chambers if required. |
Line 20: | Line 20: |
* [[LCGT/subgroup/AOS/BeamReduceTelescope1|IR Pick-off and transmit telescopes]] * [[LCGT/subgroup/AOS/BeamReduceTelescope2|Green Transmit Telescopes]] * <!> Auxiliary laser-locking system itself should be considered in MIF or IOO. The effort of system design should be separated from that of engineering and fabrication from the WBS point of view (or what-you-call system engineering) even if the person assigned to both is the same. |
* [[LCGT/subgroup/AOS/BeamReduceTelescope1|Pick-off and transmit telescopes]] * <!> Auxiliary laser-locking system itself should be considered in MIF or IOO. The effort of system designing should be separated from that of engineering and fabricating from the WBS point of view (or what-you-call system engineering) even if the person assigned to both is the same. |
Line 26: | Line 25: |
* [[LCGT/subgroup/AOS/InitialAlign1|Initial Alignment System]] | |
Line 29: | Line 27: |
* [[LCGT/subgroup/AOS/Shutter1|Beam Shutter]] | * [[LCGT/subgroup/AOS/Shutter1|Beam Shutters]] * [[LCGT/subgroup/AOS/BeamTarget1|Beam Targets in Arms]] * [[LCGT/subgroup/AOS/BeamModeProfiler1|Beam Mode Profiler]] * [[LCGT/subgroup/AOS/InitialAlign1|Initial Alignment]] |
Line 44: | Line 45: |
* [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/LCGT/subgroup/howtojoin|How to join Mailing Lists for LCGT project]] |
LCGT Auxiliary Optics Subsystem (AOS)
Contents
Objectives
The objectives of the subgroup "Auxiliary Optics System" (AOS) is to have the other LCGT subgroups design and complete the auxiliary optics that physically, logically and consistently glue the main parts of the LCGT interferometer together.
General Description
Most of the AOS shall be fit to the vacuum chambers that had been already determined when the AOS group was established. Even if the vacuum chamber was not designed considering the space allocated for AOS, AOS are required for fully operating LCGT, so we shall, by any means, pack them into the vacuum chambers if required.
References
|
||
|
||
Subsystems
Including beam baffles, output Faraday isolators, and calculation of BRDF of test masses...
Pick-off and transmit telescopes
Auxiliary laser-locking system itself should be considered in MIF or IOO. The effort of system designing should be separated from that of engineering and fabricating from the WBS point of view (or what-you-call system engineering) even if the person assigned to both is the same.
Optical lever is a kind of local sensors, but unlike other local sensors, it requires long beam lines as lever's arms, thus this should be considerd in AOS.
- Other local sensors/monitors/actuators?
- Any other optics, outside breadboard,...
- Squeezing system??
- Maybe mainly VIS group's charge and not AOS's:
Meetings