* -+This subsystem makes vibration isolation for all optics used in KAGRA.+- * -+The test mass mirrors are cooled to 20K through heat links. Though the mechanical design for the cryogenic suspensions is included by the task of this subsystem , the final stage which consists of a sapphire mirror and sapphire wires is provided by the cryogenic subsystem. The heat links are not included in this subsystem either.+- |
1. This subsystem makes vibration isolation for all optics used in KAGRA. 2. Requirement of displacement of the test mass mirrors must be less than 4x10^-20m/rtHz at 10Hz. RMS motion must be less than 0.1 um as displacement and 0.1 um/s as velocity. |
Line 15: | Line 15: |
|| - ||<style="font-weight:bold;"> [[KAGRA/Subgroups/VIS/Type-C|Type-C]] || [[KAGRA/Subgroups/VIS/Mechanics/MaragingWire|Maraging wire]] || [[KAGRA/Subgroups/VIS/Sensors/OpLev|Optical Lever (OpLev)]] || [[KAGRA/Subgroups/DGS/Projects/StepperMotor|Stepper Motor]] || - || - || || - ||<style="font-weight:bold;"> [[KAGRA/Subgroups/VIS/TMS-VIS|TMS-VIS]] || - || - || [[KAGRA/Subgroups/VIS/OpsManual/FishingRods|Fishing Rods]] || - || - || |
|| - ||<style="font-weight:bold;"> [[KAGRA/Subgroups/VIS/Type-C|Type-C]] || [[KAGRA/Subgroups/VIS/Mechanics/MaragingWire|Maraging wire]] || [[KAGRA/Subgroups/VIS/Sensors/OpLev|Optical Lever (OpLev)]] || [[KAGRA/Subgroups/DGS/Projects/StepperMotor|Stepper Motor]] || [[KAGRA/Subgroups/VIS/BIO|BIO]] || - || || - ||<style="font-weight:bold;"> [[KAGRA/Subgroups/VIS/TMS-VIS|TMS-VIS]] || - || [[KAGRA/Subgroups/VIS/ReleaseSensor|Release Sensor]] || [[KAGRA/Subgroups/VIS/OpsManual/FishingRods|Fishing Rods]] || - || - || |
Line 18: | Line 18: |
|| - || - || - || - || [[KAGRA/Subgroups/VIS/OpsManual/PicomotorPowerControlSwitch| PicomotorPowerControlSwitch]] || - || - || |
Vibration Isolation System (VIS)
Subsystem Definition
- This subsystem makes vibration isolation for all optics used in KAGRA.
- Requirement of displacement of the test mass mirrors must be less than 4x10^-20m/rtHz at 10Hz. RMS motion must be less than 0.1 um as displacement and 0.1 um/s as velocity.
Reference JGW-T1100365-v2
Design |
Suspensions |
Mechanics |
Sensors |
Actuators/Motors |
Digital System |
Diagnostics |
Concept? |
||||||
Solenoid actuator? |
--- |
|||||
- |
- |
|||||
- |
- |
|||||
- |
- |
- |
- |
|||
- |
- |
- |
- |
- |
- |
|
- |
- |
- |
- |
- |
- |
|
- |
- |
- |
- |
- |
||
- |
- |
- |
- |
- |
Meetings |
Management |
Other subsystem interfaces |
For Users |
VIS Apps |
|
||||
--- |
--- |
--- |
--- |
|
--- |
--- |
--- |
--- |
|
--- |
--- |
--- |
--- |
Links, Misic. |
Documents |
[April 28. 2020] Miyo is cleaning up the VIS wiki pages. Progress is posted here.
Old (Please arrange me)