Differences between revisions 31 and 53 (spanning 22 versions)
Revision 31 as of 2018-01-26 00:33:37
Size: 2922
Comment:
Revision 53 as of 2018-02-01 16:58:01
Size: 5735
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
= Wide Angle Baffle = = Wide Angle Baffle Cooling Test 2018 =
Line 3: Line 3:
<<MonthCalendar>> ||<<MonthCalendar(,2018,1)>>||<<MonthCalendar(,2018,2)>>||<<MonthCalendar(,2018,3)>>||
Line 9: Line 10:
 * Heat links positions (by Obuchi) [[attachment:fmkopgehpapgdkcc.png]]
Line 19: Line 20:
 * Don't forget to replace the damping magnets to SmCo ones; those will be delivered on '''''Jan 26'''''.  * Don't forget to replace the damping magnets to SmCo ones.
Line 32: Line 33:
 * Don't forget to add some heat links (Cu?) to the top of the suspension...

== PIN Assign ==
 * Summary of the pin assign of burndy connector inside the cryostat.

NOTE:
The meaning of color for thermometer cable is <<BR>>
RED = I- , YELLOW = I+ , GREEN = V- , BLACK = V+

P22
||Pin Name||Resistance|| Equipment || Assign || Comment1 || Comment2 || Connection ||
||A||75 ohm|| Thermometer || V- || Green || Cryocon CH A || ○ ||
||B||75 ohm|| Thermometer || V+ || Black || || ○ ||
||C||4 ohm|| Thermometer || I- || Red || || ○ ||
||D||4 ohm|| Thermometer || I+ || Yellow || ||
||E||75 ohm|| Thermometer || V- || Green || Cryocon CH B || ○ ||
||F||75 ohm|| Thermometer || V+ || Black || || ○ ||
||G||4 ohm|| Thermometer || I- || Red || || ○ ||
||H||4 ohm|| Thermometer || I+ || Yellow || || ○ ||
||J||75 ohm|| Thermometer || V- || Green || Cryocon CH C || ○ ||
||K||75 ohm|| Thermometer || V+ || Black || || ○ ||
||L||4 ohm|| Thermometer || I- || Red || || ○ ||
||M||4 ohm|| Thermometer || I+ || Yellow || || ○ ||
||N||Brank|| || || || || ||
||P||75 ohm|| Thermometer || V- || Green || Cryocon CH D || ○ ||
||R||75 ohm|| Thermometer || V+ || Black || || ○ ||
||S||4 ohm|| Thermometer || I- || Red || || ○ ||
||T||4 ohm|| Thermometer || I+ || Yellow || || ○ ||
||U||75 ohm|| Thermometer || V- || Green || Cryocon CH E || ○ ||
||V||75 ohm|| Thermometer || V+ || Black || || ○ ||
||W||4 ohm|| Thermometer || I- || Red || || ○ ||
||X||4 ohm|| Thermometer || I+ || Yellow || || ○ ||
||Y||Brank|| || || || || ||

P23
||Pin Name||Resistance|| Equipment || Assign || Comment1 || Comment2 || Connection ||
||A||75 ohm|| Thermometer || V- || Green || Cryocon CH F || × ||
||B||75 ohm|| Thermometer || V+ || Black || || × ||
||C||4 ohm|| Thermometer || I- || Red || || × ||
||D||4 ohm|| Thermometer || I+ || Yellow || || × ||
||E||75 ohm|| PS PD || V- || || || × ||
||F||75 ohm|| PS PD || V+ || || || × ||
||G||4 ohm|| PS LED || I- || || || × ||
||H||4 ohm|| PS LED || I+ || || || × ||
||J||75 ohm|| PS PD || V- || || || × ||
||K||75 ohm|| PS PD || V+ || || || × ||
||L||4 ohm|| PS LED || I- || || || × ||
||M||4 ohm|| PS LED || I+ || || || × ||
||N||Brank|| || || || || ||
||P||75 ohm|| PS PD || V- || || || × ||
||R||75 ohm|| PS PD || V+ || || || × ||
||S||4 ohm|| PS LED || I- || || || × ||
||T||4 ohm|| PS LED || I+ || || || × ||
||U||75 ohm|| CM Act. || I- || || || × ||
||V||75 ohm|| CM Act. || I+ || || || × ||
||W||4 ohm|| Heater || I- || || || ○ ||
||X||4 ohm|| Heater || I+ || || || ○ ||
||Y||Brank|| || || || || ||

Wide Angle Baffle Cooling Test 2018

<< <  2018 / 1 >  >>
Mon Tue Wed Thu Fri Sat Sun
1 2 3 4 5 6 7
8 9 10 11 12 13 14
15 16 17 18 19 20 21
22 23 24 25 26 27 28
29 30 31        

<< <  2018 / 2 >  >>
Mon Tue Wed Thu Fri Sat Sun
      1 2 3 4
5 6 7 8 9 10 11
12 13 14 15 16 17 18
19 20 21 22 23 24 25
26 27 28        

<< <  2018 / 3 >  >>
Mon Tue Wed Thu Fri Sat Sun
      1 2 3 4
5 6 7 8 9 10 11
12 13 14 15 16 17 18
19 20 21 22 23 24 25
26 27 28 29 30 31  

Task list

Note: some of the tasks can be done in parallel.

  • Place/install the WAB suspension.
  • Measure several relative dimensions to get useful information for the future commissioning; concretely speaking:
    • What....?
  • Test the saving mode of the WAB suspension.

  • Don't forget to replace the damping magnets to SmCo ones.

    • What is the requirement to say the damping is sufficient...?
  • Connect electric cables (with checking) in the IYC chamber.
    • 3 photosensors; in each photosensor head, two PDs should be connected parallel. Need to calibrate the response of each sensor head...

    • 2 heaters; should be connected parallel??
    • 1 coil for actuation.
    • 6 thermometers with (extended?) patch cables made of phospher bronze; the extended double twisted pare cables will be delivered on Jan 26

  • Connect 4 heat links.
  • Check oplev signals.
  • Connect cables the outside as well.
  • Make a realtime model to monitor.
  • Take interface with Tcam.
  • Make a plan to do leak check before cooling down.
  • Don't forget to add some heat links (Cu?) to the top of the suspension...

PIN Assign

  • Summary of the pin assign of burndy connector inside the cryostat.

NOTE: The meaning of color for thermometer cable is
RED = I- , YELLOW = I+ , GREEN = V- , BLACK = V+

P22

Pin Name

Resistance

Equipment

Assign

Comment1

Comment2

Connection

A

75 ohm

Thermometer

V-

Green

Cryocon CH A

B

75 ohm

Thermometer

V+

Black

C

4 ohm

Thermometer

I-

Red

D

4 ohm

Thermometer

I+

Yellow

E

75 ohm

Thermometer

V-

Green

Cryocon CH B

F

75 ohm

Thermometer

V+

Black

G

4 ohm

Thermometer

I-

Red

H

4 ohm

Thermometer

I+

Yellow

J

75 ohm

Thermometer

V-

Green

Cryocon CH C

K

75 ohm

Thermometer

V+

Black

L

4 ohm

Thermometer

I-

Red

M

4 ohm

Thermometer

I+

Yellow

N

Brank

P

75 ohm

Thermometer

V-

Green

Cryocon CH D

R

75 ohm

Thermometer

V+

Black

S

4 ohm

Thermometer

I-

Red

T

4 ohm

Thermometer

I+

Yellow

U

75 ohm

Thermometer

V-

Green

Cryocon CH E

V

75 ohm

Thermometer

V+

Black

W

4 ohm

Thermometer

I-

Red

X

4 ohm

Thermometer

I+

Yellow

Y

Brank

 

P23

Pin Name

Resistance

Equipment

Assign

Comment1

Comment2

Connection

A

75 ohm

Thermometer

V-

Green

Cryocon CH F

×

B

75 ohm

Thermometer

V+

Black

×

C

4 ohm

Thermometer

I-

Red

×

D

4 ohm

Thermometer

I+

Yellow

×

E

75 ohm

PS PD

V-

×

F

75 ohm

PS PD

V+

×

G

4 ohm

PS LED

I-

×

H

4 ohm

PS LED

I+

×

J

75 ohm

PS PD

V-

×

K

75 ohm

PS PD

V+

×

L

4 ohm

PS LED

I-

×

M

4 ohm

PS LED

I+

×

N

Brank

P

75 ohm

PS PD

V-

×

R

75 ohm

PS PD

V+

×

S

4 ohm

PS LED

I-

×

T

4 ohm

PS LED

I+

×

U

75 ohm

CM Act.

I-

×

V

75 ohm

CM Act.

I+

×

W

4 ohm

Heater

I-

X

4 ohm

Heater

I+

Y

Brank

DAQ

Real-time computer: k1???

Slot

Item

Assigned to

S/N

42

<blank>

41

<blank>

40

<blank>

39

<blank>

38

<blank>

37

<blank>

36

<blank>

35

<blank>

34

<blank>

33

<blank>

32

<blank>

31

<blank>

30

<blank>

29

<blank>

28

<blank>

27

<blank>

26

<blank>

25

<blank>

24

<blank>

23

<blank>

22

<blank>

21

<blank>

20

<blank>

19

<blank>

18

<blank>

17

<blank>

16

<blank>

15

<blank>

14

<blank>

13

<blank>

12

AI Chassis

DAC0

SN???

11

AA Chassis

ADC0

SN???

10

<blank>

9

I/O Chassis

SN???

8

<blank>

7

<blank>

6

<blank>

5

<blank>

4

<blank>

3

<blank>

2

<blank>

1

<blank>

0

<blank>